Análise exergética e optimização de uma bomba de calor com fonte no solo/água para a máxima utilização de exergia ambiental
| dc.contributor.author | Canhoto, Paulo | |
| dc.contributor.author | Reis, A. Heitor | |
| dc.contributor.author | Miguel, António F. | |
| dc.date.accessioned | 2012-01-27T17:29:45Z | |
| dc.date.available | 2012-01-27T17:29:45Z | |
| dc.date.issued | 2007-09 | |
| dc.description.abstract | The non-flow exergy potential of the near ground air with respect to the soil conditions at Évora region has been calculated from monthly averaged hourly data of temperature and specific humidity. The results show that the exergy potential is higher when either heating (wintertime) or cooling (summertime) is most required. The use of this potential for reducing the power consumption of indoor air conditioning systems through ground or water source heat pumps systems is investigated. In order to obtain an optimal operation an exergy analysis was carried out offering the opportunity of defining a new objective function for the optimisation of the use of use of exergy sources: 'In any system powered by an external exergy source optimisation is achieved when the exergy flux to the environment is minimum under the existing constraints'. | por |
| dc.identifier.authoremail | canhoto@uevora.pt | |
| dc.identifier.authoremail | ahr@uevora.pt | |
| dc.identifier.authoremail | afm@uevora.pt | |
| dc.identifier.citation | Paulo Canhoto, A. Heitor Reis, António F. Miguel, Análise exergética e optimização de uma bomba de calor com fonte no solo/água para a máxima utilização de exergia ambiental, in 3º Encontro de Pós-Graduação em Investigação e Ensino das Ciências Físicas e da Terra da Universidade de Évora, Évora, Portugal, 2007. | por |
| dc.identifier.isbn | 978-972-778-098-3 | |
| dc.identifier.pagina | 27-28 | |
| dc.identifier.principalpublicationtitle | Resumos do Terceiro Encontro de Pós-Graduação em Investigação e Ensino das Ciências Físicas e da Terra da Universidade de Évora | |
| dc.identifier.scientificarea | 286 | por |
| dc.identifier.uri | http://hdl.handle.net/10174/4419 | |
| dc.language.iso | por | por |
| dc.peerreviewed | no | por |
| dc.publisher | CGE - Geophysics Centre of Evora | por |
| dc.rights | restrictedAccess | por |
| dc.subject | Ground source heat pump | por |
| dc.subject | Exergy analysis | por |
| dc.subject | Environmental exergy | por |
| dc.subject | Optimization | por |
| dc.title | Análise exergética e optimização de uma bomba de calor com fonte no solo/água para a máxima utilização de exergia ambiental | por |
| dc.title.alternative | Exergy analysis and optimisation of a ground or water source heat pump system for maximum environmental exergy potential utilisation | por |
| dc.type | article | por |
| degois.publication.firstPage | 27 | por |
| degois.publication.lastPage | 28 | por |
| degois.publication.location | Évora, Portugal | por |
| degois.publication.title | Terceiro Encontro de Pós-Graduação em Investigação e Ensino das Ciências Físicas e da Terra da Universidade de Évora | por |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Canhoto_Reis_Miguel_2007_Analise_Exergetica_Bomba_Calor_(III_EPG_CGE).pdf
- Size:
- 178.29 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 3.89 KB
- Format:
- Item-specific license agreed upon to submission
- Description: