Análise exergética e optimização de uma bomba de calor com fonte no solo/água para a máxima utilização de exergia ambiental
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
CGE - Geophysics Centre of Evora
Abstract
The non-flow exergy potential of the near ground air with respect to the soil conditions at Évora region has been calculated from monthly averaged hourly data of temperature and specific humidity. The results show that the exergy potential is higher when either heating (wintertime) or cooling (summertime) is most required. The use of this potential for reducing the power consumption of indoor air conditioning systems through ground or water source heat pumps systems is investigated. In order to obtain an optimal operation an exergy analysis was carried out offering the opportunity of defining a new objective function for the optimisation of the use of use of exergy sources: 'In any system powered by an external exergy source optimisation is achieved when the exergy flux to the environment is minimum under the existing constraints'.
Description
Citation
Paulo Canhoto, A. Heitor Reis, António F. Miguel, Análise exergética e optimização de uma bomba de calor com fonte no solo/água para a máxima utilização de exergia ambiental, in 3º Encontro de Pós-Graduação em Investigação e Ensino das Ciências Físicas e da Terra da Universidade de Évora, Évora, Portugal, 2007.