Galvanic Corrosion of Two Non Noble Dental Alloys
| dc.contributor.author | Capelo, Sofia | |
| dc.contributor.author | Proença, L | |
| dc.contributor.author | Fernandes, JCS | |
| dc.contributor.author | Fonseca, ITE | |
| dc.contributor.editor | Antonijevic, Milan M. | |
| dc.date.accessioned | 2014-01-20T18:17:15Z | |
| dc.date.available | 2014-01-20T18:17:15Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | This study aims to evaluate the corrosion resistance of two nonnoble dental alloys, namely, the Wiron®88 (Ni–Cr–Mo) and the Remanium 2000+ (Co–Cr–Mo–W). A noble alloy, the V-Gnathos® Plus (AuPt) previously studied was also considered for the purpose of comparison. The study was conducted in artificial saliva, pH 7.1, at 37 °C, by cyclic and linear sweep voltammetry, electrochemical impedance spectroscopy and chronoamperometry. The Rp value of the alloy of high contents of Ni, the Wiron®88, was 26.2±0.2 kΩ cm2 and of the one with high contents of Co, the Remanium 2000+, was 22.5±0.6 kΩ cm2. Data from linear polarization resistance and electrochemical impedance spectroscopy lead to the same order for the resistance against corrosion. The order from the less to the more reactive alloy is: Wiron®88 → Remanium 2000+. The galvanic cell obtained by coupling the two nonnoble alloys presents very low cell potential (a few mV, -18 mV), while the galvanic cell between one noble alloy (the V-Gnathos® Plus) and the Wiron®88 showed a higher cell potential (-104 mV). Both galvanic couples, under short circuit, have lead to the release of cations, namely, Co2+, in the case of the Wiron®88|Remanium 2000+ and Ni2+ for the Wiron®88|V-Gnathos® Plus, galvanic couples, respectively, with the ionic concentrations reaching values of 12.15 and 7.30 μg L-1 (7.30 ppb), respectively. SEM micrographs obtained after 25 days immersion in artificial saliva, at 37 °C, showed the formation of well-defined pits on the surface of the two non-noble alloys. | por |
| dc.identifier.authoremail | scapelo@uevora.pt | |
| dc.identifier.authoremail | lfproenca@fc.ul.pt | |
| dc.identifier.authoremail | joao.salvador@ist.utl.pt | |
| dc.identifier.authoremail | itfonseca@fc.ul.pt | |
| dc.identifier.citation | Capelo S., Proença L., Fernandes J.C.S., Fonseca I.T.E., (2014) Galvanic corrosion of two non noble dental alloys, International Journal of Electrochemical Science, 9: 593 – 609 | por |
| dc.identifier.issn | 1452-3981 | |
| dc.identifier.scientificarea | 304 | por |
| dc.identifier.uri | http://hdl.handle.net/10174/9802 | |
| dc.language.iso | por | por |
| dc.peerreviewed | yes | por |
| dc.publisher | ESG | por |
| dc.rights | openAccess | por |
| dc.subject | dental alloys | por |
| dc.subject | Wiron®88 | por |
| dc.subject | Remanium 2000+ | por |
| dc.subject | ions release | por |
| dc.subject | galvanic couples | por |
| dc.title | Galvanic Corrosion of Two Non Noble Dental Alloys | por |
| dc.type | article | por |
| degois.publication.firstPage | 593 | por |
| degois.publication.lastPage | 609 | por |
| degois.publication.title | International Journal of Electrochemical Science | por |
| degois.publication.volume | 9 | por |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Galvanic Corrosion of Two Non Noble Dental Alloys.pdf
- Size:
- 307.04 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 3.89 KB
- Format:
- Item-specific license agreed upon to submission
- Description: