Voltametria de chumbo em cortiça
| dc.contributor.advisor | Vaz, António Manuel Neto | |
| dc.contributor.author | Sousa, João Carlos Araújo de Carvalho Caldeira da Ponte e | |
| dc.date.accessioned | 2014-10-24T16:33:18Z | |
| dc.date.available | 2014-10-24T16:33:18Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | É mostrado o teor médio conhecido de cinzas e metais em cortiça amadia, bem como o desvio-padrão e o número de referências bibliográficas. Nomeadamente de: Ca, K, Al, P, Na, Fe, Mg, Mn, Cu, Zn, Pb, Cr e Cd. De destacar (20ppm±20ppm; 5) para Pb. Foi criado um novo método quimiométrico para análise de dados, aplicado à voltametria-de-redissolução-anódica-de-impulso-diferencial. O novo método produziu uma incerteza expandida de ±0.3321ppm (ca. 1.42 %). A diferença entre os resultados do novo e do anterior método foi de 0.01ppm (23.41 e 23.40ppm). O limite-dedetecção mudou de aproximadamente 4.8 para 4ppm e o desvio-padrão-relativo aproximadamente de 9 para 6%. A voltametria-de-redissolução-anódica-de-impulso-diferencial permitiu obter, para o chumbo, o resultado de 52.85ppm±41.63ppm (77.36%) ou 32.00ppm±12.16ppm (37.98%), estudadas duas amostras de cortiça. Foi feita a optimização paramétrica e comparação com a espectrometria de absorção atómica; ### ABSTRACT: It is shown the known average concentration of ashes and metals in reproduction cork, as well as the standard-deviation and the number of bibliographic references. Namely of: Ca, K, Al, P, Na, Fe, Mg, Mn, Cu, Zn, Pb, Cr and Cd. A remark is made to (20ppm±20ppm; 5) for Pb. A new chemometric method was created for data analysis, applied to differential-pulse-anodic-stripping-voltammetry. The new method produced an expanded uncertainty of ±0.3321ppm (ca. 1.42 %). The difference between the new and old method results was 0.01ppm (23.41 and 23.40ppm). The limit-of-detection changed from approximately 4.8 for 4ppm and the relative-standard-deviation approximately from 9 to 6%. The differential-pulse-anodic-stripping-voltammetry allowed to have, for lead, the result of 52.85ppm±41.63ppm (77.36%) or 32.00ppm±12.16ppm (37.98%), after the study of two cork samples. The parametric optimization was made and atomic absorption spectrometry was used for comparison. | por |
| dc.identifier.authoremail | teses@bib.uevora.pt | |
| dc.identifier.scientificarea | 306 | por |
| dc.identifier.sharewith | Departamento de Química | por |
| dc.identifier.uri | http://hdl.handle.net/10174/11699 | |
| dc.language.iso | por | por |
| dc.publisher | Universidade de Évora | por |
| dc.rights | openAccess | por |
| dc.title | Voltametria de chumbo em cortiça | por |
| dc.type | doctoralThesis | por |