Comparison of soil pH measurement in a non tilled vineyard: conventional laboratory values vs. 3100 Veris soil pH sensor readings
| dc.contributor.author | Marques da Silva, JR | |
| dc.contributor.author | Terrón, JM | |
| dc.contributor.author | Blanco, J | |
| dc.contributor.author | Pérez, F | |
| dc.contributor.author | Galea, F | |
| dc.contributor.author | Moral, FJ | |
| dc.contributor.author | Alexandre, C | |
| dc.contributor.author | Serrano, J | |
| dc.contributor.author | Silva, LL | |
| dc.contributor.editor | Gebbers, R | |
| dc.contributor.editor | Luck, E | |
| dc.contributor.editor | Rulhmann, J | |
| dc.date.accessioned | 2013-07-22T11:08:51Z | |
| dc.date.available | 2013-07-22T11:08:51Z | |
| dc.date.issued | 2013-05-26 | |
| dc.description.abstract | This work pretends to compare the soil pH measured by the 3100 Veris sensor with the conventional soil sampling in a specific soil condition of a non tilled vineyard. Whereas high density data was obtained with the soil pH sensor, which were used to delineate a pH surface using a geostatistical algorithm, conventional laboratory values were divided in two sets, depending on their location in a 3 or a 12 years non tilled vineyards. Comparison leads to some differences, but varibility was minor when the area not mobilized for 12 years was considered. | por |
| dc.identifier.authoremail | jmsilva@uevora.pt | |
| dc.identifier.authoremail | nd | |
| dc.identifier.authoremail | nd | |
| dc.identifier.authoremail | nd | |
| dc.identifier.authoremail | nd | |
| dc.identifier.authoremail | nd | |
| dc.identifier.authoremail | cal@uevora.pt | |
| dc.identifier.authoremail | jmrs@uevora.pt | |
| dc.identifier.authoremail | llsilva@uevora.pt | |
| dc.identifier.citation | Marques, J.R., Terrón, J.M., Blanco, J., Pérez, F., Galea, F., Moral, F.J., Alexandre, C., Serrano, J., Silva, L.L. (2013) Comparison of soil pH measurement in a non tilled vineyard: conventional laboratory values vs. 3100 Veris soil pH sensor readings, in Proocedings of the 3rd Global Workshop on proximal sensing 2013, 26-29 May, Postdam, Germany, p. 101-105. ISSN 0947-7314. | por |
| dc.identifier.scientificarea | 580 | por |
| dc.identifier.sharewith | ICAAM | por |
| dc.identifier.uri | http://hdl.handle.net/10174/8629 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Leibniz Institute for Agricultural Engineering Postdam-Bornim | por |
| dc.rights | openAccess | por |
| dc.subject | soil pH | por |
| dc.subject | vineyards | por |
| dc.subject | proximal sensing | por |
| dc.title | Comparison of soil pH measurement in a non tilled vineyard: conventional laboratory values vs. 3100 Veris soil pH sensor readings | por |
| dc.type | article | por |