The Automatic Assessment of Strength and Mobility in Older Adults: A Test-Retest Reliability Study

dc.contributor.authorCollado-Mateo, Daniel
dc.contributor.authorMadeira, Pedro
dc.contributor.authorDominguez-Muñoz, Francisco J
dc.contributor.authorVillafaina, Santos
dc.contributor.authorTomas-Carus, Pablo
dc.contributor.authorParraca, Jose A.
dc.date.accessioned2020-02-21T11:58:38Z
dc.date.available2020-02-21T11:58:38Z
dc.date.issued2019
dc.description.abstractAbstract: Background: Simple field tests such as the Timed Up and Go test (TUG) and 30 s Chair Stand test are commonly used to evaluate physical function in the elderly, providing crude outcome measures. Using an automatic chronometer, it is possible to obtain additional kinematic parameters that may lead to obtaining extra information and drawing further conclusions. However, there is a lack of studies that evaluate the test-retest reliability of these parameters, which may help to judge and interpret changes caused by an intervention or differences between populations. Thus, the aim of this study was to evaluate the test-retest reliability of the Timed Up and Go test (TUG) and 30 s Chair Stand test in healthy older adults. Methods: A total of 99 healthy older adults participated in this cross-sectional study. The TUG and the 30 s Chair Stand test were performed five times and twice, respectively, using an automatic chronometer. The sit-to-stand-to-sit cycle from the 30 s Chair Stand test was divided into two phases. Results: Overall, reliability for the 30 s Chair Stand test was good for almost each variable (intraclass correlation coefficient (ICC) >0.70). Furthermore, the use of an automatic chronometer improved the reliability for the TUG (ICC >0.86 for a manual chronometer and ICC >0.88 for an automatic chronometer). Conclusions: The TUG and the 30 s Chair Stand test are reliable in older adults. The use of an automatic chronometer in the TUG is strongly recommended as it increased the reliability of the test. This device enables researchers to obtain relevant and reliable data from the 30 s Chair Stand test, such as the duration of the sit-to-stand-to-sit cycles and phases.por
dc.identifier.authoremaildanicolladom@gmail.com
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailptc@uevora.pt
dc.identifier.authoremailjparraca@uevora.pt
dc.identifier.citationCollado-Mateo D, Madeira P, Dominguez-Muñoz FJ, Villafaina S, Tomas-Carus P, Parraca JA. The Automatic Assessment of Strength and Mobility in Older Adults: A Test-Retest Reliability Study. Medicina (Kaunas). 2019;55(6). pii: E270. doi: 10.3390/medicina55060270.por
dc.identifier.doi10.3390/medicina55060270por
dc.identifier.scientificarea251por
dc.identifier.urihttp://hdl.handle.net/10174/27208
dc.language.isoengpor
dc.peerreviewedyespor
dc.rightsrestrictedAccesspor
dc.subjectinterclass correlation coefficientpor
dc.subjectstandard error of measurementpor
dc.subjectolder adultspor
dc.subjectreliability analysispor
dc.subjectphysical fitness testpor
dc.titleThe Automatic Assessment of Strength and Mobility in Older Adults: A Test-Retest Reliability Studypor
dc.typearticlepor

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
7.pdf
Size:
157.35 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: