Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool
| dc.contributor.author | Melicio, Rui | |
| dc.contributor.editor | Energy Conversion and Management-Elsevier | |
| dc.date.accessioned | 2015-12-11T12:55:22Z | |
| dc.date.available | 2015-12-11T12:55:22Z | |
| dc.date.issued | 2015-06-30 | |
| dc.description.abstract | This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. | por |
| dc.identifier.authoremail | ruimelicio@gmail.com | |
| dc.identifier.scientificarea | 492 | por |
| dc.identifier.uri | http://www.sciencedirect.com/science/article/pii/S019689041500268X | |
| dc.identifier.uri | http://hdl.handle.net/10174/16461 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Energy Conversion and Management-Elsevier | por |
| dc.rights | restrictedAccess | por |
| dc.subject | Offshore wind system | por |
| dc.subject | HVDC light | por |
| dc.subject | Four-level converter | por |
| dc.subject | Unbalance capacitor voltage | por |
| dc.subject | Rectifier malfunction | por |
| dc.subject | Smart grid | por |
| dc.title | Simulation of rectifier voltage malfunction on OWECS, four-level converter, HVDC light link: Smart grid context tool | por |
| dc.type | article | por |