Transport of the smoke plume from Chiado’s fire in Lisbon (Portugal) sensed by atmospheric electric field measurements

dc.contributor.authorConceição, Ricardo
dc.contributor.authorMelgão, Marta
dc.contributor.authorSilva, Hugo
dc.contributor.authorReis, A. Heitor
dc.contributor.editorSpringer
dc.date.accessioned2016-01-29T11:29:57Z
dc.date.available2016-01-29T11:29:57Z
dc.date.issued2015-03-31
dc.description.abstractThe Chiado’s fire that affected the city centre of Lisbon (Portugal) occurred on 25th August 1988 and had a significant human and environmental impact. This fire was considered the most significant hazard to have occurred in Lisbon city centre after the major earthquake of 1755. A clear signature of this fire is found in the atmospheric electric field data recorded at Portela meteorological station about 8 km NE from the site where the fire started at Chiado. Measurements were made using a Benndorf electrograph with a probe at 1-m height. The atmospheric electric field reached 510 V/m when the wind direction was coming from SW to NE, favourable to the transport of the smoke plume from Chiado to Portela. Such observations agree with predictions using Hysplit air mass trajectory modelling and have been used to estimate the smoke concentration to be ~0.4 mg/m3. It is demonstrated that atmospheric electric field measurements were therefore extremely sensitive to Chiado’s fire. This result is of particular current interest in using networks of atmospheric electric field sensors to complement existing optical and meteorological observations for fire monitoring.por
dc.identifier.authoremaill27283@alunos.uevora.pt
dc.identifier.authoremailmartamelgao@gmail.com
dc.identifier.authoremailhgsilva@uevora.pt
dc.identifier.authoremailahr@uevora.pt
dc.identifier.citationRicardo Conceição, Marta Melgão, Hugo G. Silva, Keri Nicoll, Richard G. Harrison, António H. Reis, “Transport of the smoke plume from Chiado’s fire in Lisbon (Portugal)sensed by atmospheric electric field measurements”, Air Qual. Atmos.Health,pp 1-9 (2015)por
dc.identifier.doi10.1007/s11869-015-0337-4por
dc.identifier.urihttp://link.springer.com/article/10.1007%2Fs11869-015-0337-4#/page-1
dc.identifier.urihttp://hdl.handle.net/10174/17060
dc.language.isoengpor
dc.peerreviewedyespor
dc.rightsopenAccesspor
dc.subjectsmokepor
dc.subjectatmospheric electric fieldpor
dc.titleTransport of the smoke plume from Chiado’s fire in Lisbon (Portugal) sensed by atmospheric electric field measurementspor
dc.typearticlepor
degois.publication.titleAir Quality, Atmosphere & Healthpor

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Transport of the smoke plume from Chiado’s fire in Lisbon (Portugal) sensed by atmospheric electric field measurements.pdf
Size:
2.37 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: