Furosemide in water matrix: HPLC-UV method development and degradation studies,Furosemida em matriz de água: Desenvolvimento de um método HPLC-UV e estudos de degradação

dc.contributor.authorMachado, A.I.
dc.contributor.authorFragoso, R.
dc.contributor.authorDordio, A.V.M.N.B.
dc.contributor.authorDuarte, E.
dc.date.accessioned2021-07-12T13:53:56Z
dc.date.available2021-07-12T13:53:56Z
dc.date.embargo2020-03
dc.date.issued2020-03
dc.description.abstractThis study developed a method for furosemide quantification through high performance liquid chromatographic technique. Special attention was given to solute loss and storage stability due to furosemide’s low solubility and photosensitivity, respectively. The performance of Nylon and PVDF filters was tested in a 2 mg.L-1 furosemide solution. PVDF filters showed better recovery capacity and therefore are more suitable for furosemide filtration. Over eight days, three different storage conditions were studied to access furosemide degradation susceptibility: (i) exposure to light at room temperature, (ii) storage at room temperature without exposure to light, and (iii) storage at 4ºC without exposure to light. The study demonstrated that after 48 h under natural light exposure furosemide was completely degraded. Furosemide solution stored in the dark was stable. Storage temperature did not seem to affect furosemide concentration. The study shows that the selection of more suitable filter and storage conditions for furosemide determination is crucial to avoid underestimation errors.por
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailavbd@uevora.pt
dc.identifier.authoremailnd
dc.identifier.citationMachado, A.I.; Fragoso, R.; Dordio, A.V.M.N.B.; Duarte, E.. "Furosemide in water matrix: HPLC-UV method development and degradation studies,Furosemida em matriz de água: Desenvolvimento de um método HPLC-UV e estudos de degradação". Revista Ambiente e Agua 15:1 (2020)por
dc.identifier.doi10.4136/ambi-agua.2406por
dc.identifier.scientificarea304por
dc.identifier.sharewithQUI - Publicações - Artigos em Revistas Internacionais Com Arbitragem Científicapor
dc.identifier.urihttps://doi.org/10.4136/ambi-agua.2406
dc.identifier.urihttp://hdl.handle.net/10174/30007
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherInstitute for Environmental Research in Hydrographic Basins (IPABHi)por
dc.rightsopenAccesspor
dc.subjectfilter retentionpor
dc.subjectpharmaceuticalpor
dc.subjectphotodegradationpor
dc.titleFurosemide in water matrix: HPLC-UV method development and degradation studies,Furosemida em matriz de água: Desenvolvimento de um método HPLC-UV e estudos de degradaçãopor
dc.typearticle
degois.publication.firstPage1por
degois.publication.issue1por
degois.publication.lastPage12por
degois.publication.locationBrasilpor
degois.publication.titleRevista Ambiente e Aguapor
degois.publication.volume15por

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AIMachado-2020-RevAmbientAgua_15_e2406.pdf
Size:
420.89 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: