Cox proportional hazards model used for predictive analysis of the energy consumption of healthcare buildings

dc.contributor.authorGonzález-Domínguez, Jaime
dc.contributor.authorSánchez-Barroso, G
dc.contributor.authorSanz-Calcedo, J
dc.contributor.authorde Sousa Neves, N
dc.date.accessioned2023-02-28T10:22:47Z
dc.date.available2023-02-28T10:22:47Z
dc.date.issued2022
dc.description.abstractThe energy consumption of healthcare buildings is very high due to their 24/7 functioning and the demand of electro-medical equipment. This excessive energy consumption cannot be attributed to a single factor. The objective of this research was to apply Cox proportional hazards model to predict the probability of energy overconsumption in healthcare buildings for different functional variables. A reference energy consumption index was established from a retrospective analysis of the monthly consumption of 64 healthcare buildings during the period 2015–2019. Functional parameters (construction, facilities, demographics, and climate) were selected as candidates for Cox proportional hazards model. The study found that the variables related to facilities and demographics significantly influence the semi-parametric model of energy consumption. Their influence was quantified, and the validity of the proposed model was verified graphically. Having more than 10,000 users was found to result in a 124% greater probability of exceeding the reference energy consumption, 97.4% greater with an installed power above 60 kW, and 94.6% greater if the town in which the healthcare building is located has more than 5000 inhabitants, and 69.4% greater if a heat pump is not used for air-conditioning. The Cox proportional hazards model was shown to be an advanced tool useful for quantifying the influence of various functional variables on the excess energy consumption of healthcare buildings. The results of the research generate objective information to establish, on the one hand, criteria for designing and renovating healthcare buildings and, on the other hand, care planning strategies.por
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailnneves@uevora.pt
dc.identifier.citationGonzález-Domínguez, J., Sánchez-Barroso, G., Sanz-Calcedo, J., de Sousa Neves, N. (2022) Cox proportional hazards model used for predictive analysis of the energy consumption of healthcare buildings, Energy and Buildings 257:111784, https://DOI: 10.1016/j.enbuild.2021.111784 (Factor de impacto: 7.13)por
dc.identifier.doihttps://DOI: 10.1016/j.enbuild.2021.111784por
dc.identifier.scientificarea521por
dc.identifier.urihttps://DOI: 10.1016/j.enbuild.2021.111784
dc.identifier.urihttp://hdl.handle.net/10174/34799
dc.language.isoporpor
dc.peerreviewedyespor
dc.publisherEnergy and Buildingspor
dc.rightsrestrictedAccesspor
dc.subjectCox proportional hazard modelpor
dc.subjectPrimary healthcare centrepor
dc.subjectEnergy consumptionpor
dc.subjectSemi-parametric modelpor
dc.subjectSustainabilitypor
dc.subjectHealthcare engineeringpor
dc.titleCox proportional hazards model used for predictive analysis of the energy consumption of healthcare buildingspor
dc.typearticlepor

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gonzalez_Dominguez_2022.pdf
Size:
900.95 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: