Construction Solutions, Cost and Thermal Behavior of Efficiently Designed Above-Ground Wine-Aging Facilities

dc.contributor.authorGómes-Villarino, M.T.
dc.contributor.authorBarbero-Barrera, M.M.
dc.contributor.authorCañas, I.
dc.contributor.authorRamos-Sanz, A.
dc.contributor.authorBaptista, F.J:
dc.contributor.authorMazarrón, F.R.
dc.contributor.editorŠeduikyte, L.
dc.contributor.editorKolarik, J.
dc.date.accessioned2024-05-24T14:53:10Z
dc.date.available2024-05-24T14:53:10Z
dc.date.issued2024
dc.description.abstractThe wine industry requires a considerable amount of energy, with an important fraction cor responding to the cooling and ventilation of above-ground aging warehouses. The large investments made in aging facilities can compromise the viability and competitiveness of wineries if their design is not optimized. The objective of this study was to provide guidance for the efficient design of new above-ground warehouses. To this end, multiple construction solutions (structure, envelopes, levels of integration, etc.) were characterized, and their costs and the resulting interior environments were analyzed. The results offer a comprehensive view of potential construction solutions and benchmark price ranges for viable and profitable designs. With a total cost of 300 EUR/m2 , an average damping of 98% per day can be achieved. Increasing the costs does not imply better effectiveness. A double enclosure with internal insulation—with or without an air chamber—can achieve excellent results. Greater integration as a result of several enclosures being in contact with other rooms and/or the terrain allows for a high effectiveness to be achieved without air conditioning. Perimeter glazing and ventilation holes can reduce the effectiveness of the construction, resulting in greater instability and a lower damping capacity.por
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailnd
dc.identifier.authoremailfb@uevora.pt
dc.identifier.authoremailf.ruiz@upm.es
dc.identifier.citationGÓMEZ-VILLARINO M.T., BARBERO-BARRERA M.D.M., CAÑAS I., RAMOS-SANZ A. BAPTISTA F., MAZARRÓN F.R (2024). Construction Solutions, Cost and Thermal Behavior of Efficiently Designed Above-Ground Wine-Aging Facilities. Buildings 14, 655. https://doi.org/10.3390/buildings14030655por
dc.identifier.doi10.3390/buildings14030655por
dc.identifier.scientificarea580por
dc.identifier.sharewithpartilhar com MEDpor
dc.identifier.urihttp://hdl.handle.net/10174/36728
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherMDPIpor
dc.rightsopenAccesspor
dc.subjectwinepor
dc.subjectagingpor
dc.subjectabove-ground warehousepor
dc.subjectconstructionpor
dc.subjectcostpor
dc.subjectdampingpor
dc.titleConstruction Solutions, Cost and Thermal Behavior of Efficiently Designed Above-Ground Wine-Aging Facilitiespor
dc.typearticlepor

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gomez-Villarino et al_Buildings_2024.pdf
Size:
765.74 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: