Vazão em soleiras controladas ou não por comportas

dc.contributor.advisorRijo, Manuel
dc.contributor.authorSilva, Carlos Otero Águas da
dc.date.accessioned2016-08-04T14:55:08Z
dc.date.available2016-08-04T14:55:08Z
dc.date.issued2016
dc.description.abstractOs controladores de caudal, normalmente implementados em sistemas Supervisory control and data acquisition (SCADA), apresentam uma grande relevância no controlo automático de canais de adução. Para garantir que os controladores de caudal sejam fiáveis em todo o seu domínio de funcionamento (em situações de escoamento com ressalto livre ou submerso e de transição entre escoamentos com ressalto livre e ressalto submerso) foram comparados os resultados dos ensaios experimentais com diferentes métodos de cálculo da vazão em comportas e/ou sobre soleiras. O programa de ensaios foi realizado nos canais laboratorial e experimental da Universidade de Évora. Foram realizados ensaios em comportas planas verticais e em soleiras do tipo Waterways Experiment Station (WES) controladas ou não por comportas planas verticais. Em ambos os casos, foram contempladas as situações de escoamento com ressalto livre e submerso. Os resultados obtidos mostram que: a) para as comportas, o método Rajaratnam e Subramanya (1967a) conduz a bons resultados com um erro percentual médio absoluto MAPE < 1% para o escoamento com ressalto livre e MAPE < 4% para o submerso; a transição entre escoamentos foi identificada corretamente por este método; b) para as soleiras, obtiveram-se bons resultados para o escoamento com ressalto livre para o método USACE (1987), com MAPE < 2%, e para o submerso através do método Alves e Martins (2011), com MAPE < 5%; a transição entre escoamentos pode ser considerada adequada de acordo com a curva experimental de Grace (1963); c) para soleiras controladas por comporta, conseguiram-se bons resultados para o escoamento com ressalto livre recorrendo à equação dos orifícios de pequenas dimensões, com MAPE < 1, 5%, e para o submerso com a equação dos orifícios totalmente submersos com MAPE < 1, 6%; em ambos os casos foi necessária calibração do coeficiente de vazão; a transição entre escoamentos foi adequada pelo método de Grace (1963). Com base nos resultados obtidos, foi possível definir um algoritmo de vazão generalizado para comportas e/ou soleiras que permite a determinação da vazão para as situações de escoamento com ressalto livre e submerso incluindo a transição entre escoamentos; ABSTRACT: Flow controllers, usually implemented in Supervisory Control and Data Acquisition (SCADA) systems, are very important in the automatic control of irrigation canal systems. To ensure that flow controllers are reliable for the entire operating range (free or submerged flow and flow transitions) the experimental results were compared with different methods of flow measurement for gates and/or weirs. The test program was conducted in the laboratory flume and in the automatic canal of the University of ´Evora. Tests were carried in sluice gates and in broad-crested weirs controlled or not by sluice gate. In both cases free and submerged flow conditions were analyzed. The results show that: a) for the sluice gates, the method of Rajaratnam e Subramanya (1967a) leads to good results with a mean absolute percentage error (MAPE) < 1% for free flow and MAPE < 4% for submerged flow. The transition between flows is correctly identified by this method; b) for the uncontrolled weir, good results were obtained for free flow with the method USACE (1987) with MAPE < 2%, and for submerged flow by the method Alves e Martins (2011) with MAPE < 5%. The transition between flows can be accurately defined by the experimental curve of Grace (1963); c) for the controlled weir, good results were achieved for the free flow with the small orifice equation with MAPE < 1.5% and for submerged flow with the submerged orifice equation with MAPE < 1.6%; in both cases the calibration of the discharge coefficient is needed. The transition between flows can be accomplished through Grace (1963) method. Based on the obtained results, it was possible to define a generalized flow algorithm for gates and/or weirs that allows flow determination for free and submerged flow conditions including the transition between flows.por
dc.identifier.authoremailcarlos-otero@sapo.pt
dc.identifier.scientificarea214por
dc.identifier.sharewithDepartamento de Engenharia Ruralpor
dc.identifier.tid101513402
dc.identifier.urihttp://hdl.handle.net/10174/18725
dc.language.isoporpor
dc.publisherUniversidade de Évorapor
dc.rightsopenAccesspor
dc.subjectEquações de vazãopor
dc.subjectSoleira espessa do tipo WESpor
dc.subjectRessalto hidraúlico livrepor
dc.subjectRessalto hidraúlico submersopor
dc.subjectComportapor
dc.subjectComporta plana verticalpor
dc.subjectBroad-crested weirpor
dc.subjectFlow equationspor
dc.subjectFree and submerged hydraulic jumppor
dc.subjectGatepor
dc.subjectSluice gatepor
dc.titleVazão em soleiras controladas ou não por comportaspor
dc.typedoctoralThesis
thesis.degree.nameDissertação de Doutoramento em Ciências Agrárias e Ambientaispor

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Carlos Otero Jul2016.pdf
Size:
9.54 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: