THE DIAGNOSTIC Ovi ABSORPTION LINE IN DIFFUSE PLASMAS: COMPARISON OF NON-EQUILIBRIUM IONIZATION STRUCTURE SIMULATIONS TO FUSE DATA

dc.contributor.authorde Avillez, Miguel
dc.contributor.authorBreitschwerdt, Dieter
dc.date.accessioned2012-12-02T23:13:21Z
dc.date.available2012-12-02T23:13:21Z
dc.date.issued2012-12
dc.description.abstractThe nature of the interstellar O vi in the Galactic disk is studied by means of a multi-fluid hydrodynamical approximation, tracing the detailed time-dependent evolution of the ionization structure of the plasma. Our focus is to explore the signature of any non-equilibrium ionization condition present in the interstellar medium using the diagnostic O vi ion. A detailed comparison between the simulations and FUSE data is carried out by taking lines of sight (LOS) measurements through the simulated Galactic disk, covering an extent of 4 kpc from different vantage points. The simulation results bear a striking resemblance with the observations: (1) the N(O vi) distribution with distance and angle fall within the minimum and maximum values of the FUSE data; (2) the column density dispersion with distance is constant for all the LOS, showing a mild decrease at large distances; (3) O vi has a clumpy distribution along the LOS; and (4) the time-averaged midplane density for distances >400 pc has a value of (1.3–1.4) × 10−8 cm−3. The highest concentration of O vi by mass occurs in the thermally stable (103.9 K < T 104.2 K; 20%) and unstable (104.2 K < T < 105 K; 50%) regimes, both well below its peak temperature in collisional ionization equilibrium, with the corresponding volume filling factors oscillating with time between 8%–20% and 4%–5%, respectively. These results may also be relevant for intergalactic metal absorption systems at high redshifts.por
dc.identifier.authoremailmavillez@galaxy.lca.uevora.pt
dc.identifier.authoremailnd
dc.identifier.doi10.1088/2041-8205/761/2/L19
dc.identifier.paginaL19
dc.identifier.principalpublicationtitleThe Astrophysical Journal Letters
dc.identifier.scientificarea343por
dc.identifier.urihttp://hdl.handle.net/10174/6175
dc.identifier.volume761
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherIOPsciencepor
dc.rightsrestrictedAccesspor
dc.subjectatomic processespor
dc.subjecthydrodynamicspor
dc.subjectISM: generalpor
dc.subjectplasmaspor
dc.subjectultraviolet: ISMpor
dc.titleTHE DIAGNOSTIC Ovi ABSORPTION LINE IN DIFFUSE PLASMAS: COMPARISON OF NON-EQUILIBRIUM IONIZATION STRUCTURE SIMULATIONS TO FUSE DATApor
dc.typearticlepor

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2012ApJL...761..2..L19deAvillez.pdf
Size:
766.25 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.89 KB
Format:
Item-specific license agreed upon to submission
Description: